HPLC Analysis: A Step-by-Step Guide for Beginners
Table of Contents
High pressure is used in high performance liquid chromatography to force a liquid sample down a column that has a stationary phase inside of it. Effective chemical compound separation is made possible by this approach, which also works with tiny molecules and polymers. HPLC is used to monitor environmental pollutants, such as pesticides and heavy metals, in water and soil samples. HPLC is able to deliver accurate analytical results by taking advantage of the variations in how the stationary phase and sample components interact. HPLC is a crucial bioanalytical method for the quantification of biomolecules, such as proteins and peptides, in biological samples.
A sample solution is made and then injected into the HPLC apparatus to start the process. The components are separated when the sample passes through the column according to how each one interacts differently with the stationary phase. It is possible to determine the timing and intensity of each component by detecting their elution. along with gas chromatography (GC), is a fundamental chromatographic technique for the separation and analysis of complex mixtures.
1.Overview of the HPLC Analysis Method
High performance liquid chromatography, or HPLC, is a fantastic analytical method for tiny molecules, polymers, and biopolymers, among other chemical substances. To create a solution with this procedure, a sample must first be dissolved. Subsequently, this solution is pumped into a resin-filled “column” that will interact with the sample.
The sample will travel through the “column” more slowly as a result, and it will be recognised when it emerges on the opposite side. This gives you the ability to determine the sample’s intensity as well as the moment at which it is discovered.
With HPLC, components are separated according to how they interact with a stationary phase and a mobile phase. A liquid that runs through the column is known as the mobile phase, while the stationary phase is made up of porous material packed into a column. The components are separated according to their physical and chemical characteristics when they interact with the stationary phase, including size, affinity, and polarity.
2.Chromatography Types
What molecules you can separate and the type of chromatography you are performing depend on the makeup of the column resin.
Effective HPLC method development requires careful consideration of factors such as column selection, mobile phase composition, and flow rate.
Normal Phase: The buffer passing through the system is non-polar, and the column is packed with polar silica particles. Polar particles will adhere to the silica more readily and retain their position on the material longer than non-polar molecules after injection.
Phase Reversal: The column is full of silica particles with long hydrocarbons on their surface, which are hydrophobic in nature. Polar buffers, like acetonitrile/water or methanol/water combinations, Chromatographic Techniques, are used in the system. Hydrophobic molecules will therefore adhere to the resin more and remain there for a longer period of time.
3.Key Components of HPLC Analysis
Mobile Phase: The liquid solvent that moves the sample through the column is one of the main components of the HPLC mobile phase . The separation process can be greatly impacted by the mobile phase’s makeup. Effective HPLC method development requires careful consideration of factors such as column selection, mobile phase composition, and flow rate. A typical HPLC system consists of a pump, injector, column, detector, and data acquisition system.
Pump: High-pressure pumps are used in HPLC systems to provide a steady flow of the mobile phase, which is essential for preserving separation efficiency.
The injector: is the part that adds the sample to the stream of the mobile phase. Its purpose is to deliver accurate and consistent injections.
Column: The stationary phase material that interacts with the components of the sample is packed into the column, which is the central component of the HPLC system. To get the best possible separation, the stationary phase selection is essential.
Detector: A detector analyzes the components and determines their concentration after they leave the column. Typical techniques for detection include UV-Vis spectroscopy, radiation, as well as mass spectrometry.
Data System: A chromatography data system (CDS) creates a chromatogram, which shows the separation findings, after processing the detector’s signals.
4. HPLC analysis depends on Sample Set-Up
A precise HPLC analysis depends on sample preparation. There are multiple steps involved:
Dissolution: Use a suitable solvent that works with both the mobile phase and the HPLC equipment to dissolve the sample. The solubility of the analytes and the intended separation conditions influence the solvent selection.
Filtration: Use a filter with a pore size suitable for the analysis to remove any particles from the sample. This keeps the column clear of obstructions and guarantees that the mobile phase flows freely.
Derivatization : In certain circumstances, the analytes may require chemical modification in order to enhance their capabilities for separation or detection. We call this procedure “derivatization.”
5.Selection and Optimization of the Mobile Phase
In HPLC, the selection of mobile phase has a major effect on separation efficiency. Both the stationary phase and the analytes should be compatible with the mobile phase. Water, acetonitrile, methanol, and tetrahydrofuran are typical solvents used in HPLC. Effective HPLC method development requires careful consideration of factors such as column selection, mobile phase composition, and flow rate.
Optimizing the mobile phase includes:
Gradient elution: A technique for improving the separation of complex materials by using a variety of solvents with different polarity.
Preparing the buffer: Including buffers to regulate the mobile phase’s pH and enhance some analytes’ retention.
Additives: Employing surfactants or ion-pairing reagents as additives to improve the separation of particular analytes.
6.Column Selection and Optimization
One essential part of the HPLC system is the column. The kind of analytes, the required analysis duration, and the desired separation selectivity all influence the column selection. Reversed-phase, normal-phase, ion-exchange, and size-exclusion columns are examples of common column types.
Column conditioning entails:
Equilibration: Making sure the column is saturated with solvent by flushing it with the mobile phase.
Cleaning: To keep the column functioning properly, remove any pollutants or impurities.
7.Dosing and Distillation
An autosampler or manual injection valve is used to introduce the sample into the flow stream. The mobile phase then moves the sample across the column, separating the constituents according to how they interact with the stationary phase.
Affecting factors for separation:
Rate of flow: The velocity at which the phase in motion passes through the column.
Temperature: The column’s temperature has an impact on the effectiveness of the separation process and retention periods.
Column diameter and length: The column’s measurements have an impact on the speed of analysis and separation effectiveness.
8. Identifying and Analyzing Data
An appropriate detector is used to detect the separated components as they elute from the column. Typical detectors consist of:
UV detector: Finds substances that absorb ultraviolet light.
Analytes that release fluorescence: when stimulated by UV light are detected by a fluorescence detector.
Refractive index detector: Identifies variations in the mobile phase’s refractive index brought on by the presence of analytes.
Analyte structural information is provided using a mass spectrometer and Analytical Chemistry
A chromatogram, which displays the retention period and peak area of each analyte, is created from the detector signal. The peak area and the analyte concentration are proportionate.
9. HPLC Analytical quantitative methods:
Plotting a calibration curve that connects the peak area to the concentration requires first preparing a number of standard solutions with known analyte concentrations.
Conventional addition technique: Measure the peak regions of the sample after adding known quantities of the analyte. Matrix effects can be adjusted using this technique. Accurate quantitative analysis using HPLC can be achieved by employing appropriate calibration methods and data processing techniques.
10.For preparing the HPLC Analytical apparatus:
- Ensure that every buffer is configured.
- After opening the purge valve, give the system a five-minute purge.
- Place your samples in the tray of the autosampler.
- Give up the purging.
- Put the purge valve closed.
- To equilibrate the column, run the system for 10 minutes at a typical flow rate of 1 ml/min with your buffer.
- Ensure that your pressure remains constant, with fluctuations of no more than two to three bars.
- Establish your workflow and procedure.
- Run a standard either as a part of the same sequence or before your actual samples.
Wide Range of Stock:
We provide a large range of laboratory supplies, including Chemicals, Consumables, Instruments, Standards, Gradient HPLC.
Researchers can be guaranteed to locate all the information they require in one location with this extensive collection. If you work in any branch of science, including chemistry, biology, or another scientific discipline, Valency Lab has the tools you need to be successful.
In summary
HPLC is a crucial bioanalytical method for the quantification of biomolecules, such as proteins and peptides, in biological samples. HPLC is employed in food analysis to determine the presence and levels of various compounds, including additives, contaminants, and natural constituents. A robust analytical method with several uses is high-performance liquid chromatography (HPLC). You can successfully use HPLC for your research or analytical needs by comprehending the underlying concepts and adhering to the instructions provided in this tutorial. HPLC is used to monitor environmental pollutants, such as pesticides and heavy metals, in water and soil samples.
To obtain the appropriate separation and sensitivity, don’t forget to optimized the sample preparation, mobile phase, column, and detection parameters. When used properly, HPLC can offer insightful information on the makeup of intricate mixes. HPLC is indispensable in pharmaceutical analysis for quality control, impurity profiling, and drug development.
Apart from the materials on our website, the following helpful external resources will help you improve your understanding of HPLC Analysis :
The American Chemical Society (ACS)